Features

Multiple-Echo for reliable, accurate through coating measurements
Single-Echo and Echo-Echo measuring modes with twin crystal probes for extreme corrosion and back wall pitting
A-scan display
Real time B-scan display
Manual and automatic gain control
Comprehensive data logging capabilities
Bluetooth connectivity
MSI™ (Measurement Stability Indicator) used in Single‑Echo and Echo-Echo measurement modes
Large bright colour LCD screen with back light
Deep-coat mode, measure through coatings up to 20 mm thick
Wrist mountable
Minimum / maximum measurement limit functions with visual and vibrate alert
Intuitive easy to use menu
Extremely rugged enclosure – shock and impact to US MIL STD 810G
Environmental sealing to IP67 – US MIL STD 810G
Cygnus echo strength bars to assist quick measurements
Buttons integral with the TPE moulding and designed for min 100,000 depressions.

Description

CYGNUS 6+ PRO MULTI-MODE ULTRASONIC THICKNESS GAUGE

 

FEATURES:

Multiple-Echo for reliable, accurate through coating measurements
Single-Echo and Echo-Echo measuring modes with twin crystal probes for extreme corrosion and back wall pitting
A-scan display
Real time B-scan display
Manual and automatic gain control
Comprehensive data logging capabilities
Bluetooth connectivity
MSI™ (Measurement Stability Indicator) used in Single‑Echo and Echo-Echo measurement modes
Dual display – large front LCD display and end-mounted OLED display with grayscale setting for bright sunlight
Deep-coat mode, measure through coatings up to 0.787 inch (20 mm) thick
Wrist mountable
Minimum / maximum measurement limit functions with visual and vibrate alert
Intuitive easy to use menu
Extremely rugged enclosure – shock and impact to US MIL STD 810G
Environmental sealing to IP67 – US MIL STD 810G
Cygnus echo strength bars to assist quick measurements
Buttons integral with the TPE moulding and designed for min 100,000 depressions.

 

 

 

DATA LOGGING KEY FEATURES:

3 available formats: sequential, grid and template
Add comment
Add radial points
Versatile data logging which allows measurements and A‑scans to be saved
5,000 measurement points (including A-scan) per record
Records are saved to a removable SD card
Selectable Auto-Log feature
Records easily transferred via gauge USB port to *Cyglink software where they can be exported to a CSV file or a PDF report.
*For more details, visit the CygLink Software page in PRODUCTS > THICKNESS GAUGING ACCESSORIES section.

 

Probes:

CYGNUS PROBES AND CABLES

Stainless Steel INOX Single Crystal Probes
The INOX probes have an updated ergonomic design and an easier to read frequency, identification and serial numbering. All frequencies of INOX probes have a black face and a colour coding ring to identify probe frequency.
Used in Multiple-Echo mode, these probes require no zeroing, have a high linear accuracy, are ideal for general thickness gauging and on pipes and have replaceable wear membrane for long life.

Stainless Steel INOX Twin Crystal Probes
Used in Echo-Echo and Single-Echo modes and focussed ultrasound beam with improved measurability on extreme back wall corrosion and pitting.

 

Probe Options
For optimum performance of the ultrasonic thickness gauge it is essential to utilise the appropriate probe for the specific material being tested. Here below are the probe options available.

Single crystal probes: 
6 mm – 5 MHz (S5A)
13 mm – 2.25 MHz (S2C (standard)), 3.5 MHz (S3C) or 5 MHz (S5C)
19 mm – 2.25 MHz (S2D)
Twin crystal probes: 5 mm – 7.5 MHz (T7A)
8 mm – 5 MHz (T5B (standard))
12 mm – 2 MHz (T2C (for attenuative materials such as cast metals, plastics and composites))

Cygnus Cables

Using standard industry connectors the probe lead uses a custom made over moulded cable that offers superior flexibility and resistance to oils and ultraviolet light. The cable will not stiffen after exposure to ultraviolet light.

 

Options:

MULTI-MEASURING MODE
Multiple-Echo uses three back wall echoes and measures remaining metal thickness while ignoring coatings. All measurements are error checked using 3 return echoes to give repeatable, reliable results. Accepted by all major classification societies. Uses single crystal probes for linear accuracy (and no probe zero required).

Echo-Echo uses two back wall echoes and measures remaining metal thickness while ignoring coatings up to 0.04″ (1 mm) thick using twin crystal probes for improved detection of back wall corrosion and pitting.

Single-Echo uses one back wall echo, measures remaining metal thickness on uncoated surfaces and is possibly helpful for areas with extreme front face or back wall corrosion and pitting. Effective on highly attenuative materials such as cast metals, plastics and composites.

MSI™ (MEASUREMENT STABILITY INDICATOR)
This clever technique helps ensure only stable measurements are displayed in Echo-Echo and Single-Echo modes. Displayed measurements change color from red to green and vibrate alert to indicate a stable reading.

FLEXIBLE HANDLING
Along with the wrist and neck straps supplied in the kit there is also an optional belt clip, offering a range of flexible handling solutions for all types of applications.

 

 

Specifications:

Measuring Modes Multiple-Echo using 3 sound pulses to ignore coatings up to 0.787 inch (20 mm) thick
Echo-Echo using 2 sound pulses to ignore coatings up 0.039 inch (1 mm) thick
Single-Echo using 1 sound pulse
Materials Sound velocities between 1000 – 9000 m/s – covers virtually all common engineering materials
Accuracy ±0.1 mm or 0.1% of thickness measurement, whichever is greatest, when calibrated in accordance with Cygnus Instruments calibration procedure
Resolution Multiple-Echo mode – 0.1 mm or 0.05 mm
Single-Echo and Echo-Echo modes – 0.01 mm
Measurement Range in Steel Single crystal probes in Multiple-Echo:

 

  • 3 – 250 mm with 2.25 MHz probe (S2C/D)
  • 2 – 150 mm with 3.5 MHz probe (S3C)
  • 1 – 50 mm with 5 MHz probe (S5C/A)

Twin crystal probes in Single-Echo:

  • 2.5 – 250 mm with 2 MHz probe (T2C)
  • 1 – 200 mm with 5 MHz probe (T5B)
  • 0.8 – 50 mm with 7.5 MHz probe (T7A)

Twin crystal probes in Echo-Echo:

  • 5 – 50 mm with 2 MHz probe (T2C)
  • 3 – 50 mm with 5 MHz probe (T5B)
  • 3 – 25 mm with 7.5 MHz probe (T7A)
Connector Twin Lemo 00
Power 3 x AA batteries
Battery Life 10 hours minimum
Electronics Dual channel pulser
Display 2.4″ quarter VGA LCD and end-mounted OLED (rotatable)
Size 132 x 82 x 34 mm
Weight 300 grams (inc. batteries)
Operating Temp. -10°C to 50°C
Data Logging Capacity up to 5000 points including A-scans
Computer Software CygLink allows remote logging and viewing of A-scan graphs.
Survey and report generation to PDF file.
Data can be exported as a .CSV file.
Graphic analysis of data and statistical calculations.
Designed for Windows 7 and Windows 8.
Environmental Rating IP67 (dust tight and immersion – 1 metre for 30 mins)
Explosive Atmosphere: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL STD 810G Method 511.5, Procedure I
MIL STD 810G Method 501.6 (high temp +55°C)
MIL STD 810G Method 502.6 (low temp -20°C)
MIL STD 810G Method 507.6 (humidity 95%)
MIL STD 810G Method 512.6 (immersion – 1 metre for 30 mins)
Shock and Impact MIL STD 810G Method 514.7 (vibration – 1 hour each axis)
MIL STD 810G Method 516.7 (shock 20g – 11ms half sine shock pulse, 40g 11ms in each axis)
MIL STD 810G Method 516.7 (26 drops – transit drop 1.22 m)
Compliance CE, British Standard BS EN 15317:2013
Environmental RoHS, WEEE compliant
Warranty 3 years on gauge and 6 months on probe

 

Downloads

 Cygnus6plus-data-sheet-Comm-Co.pdf

 

 
For orders under € 450 we charge € 25 order costs.
Prices shown on this website are before taxes, currency changes and shipping costs.
For an accurate price please contact our sales team at info@comm-co.com

 

*Prices as shown on this store are indicational and subject to 21% tax,
currency changes and shipping costs. For an accurate and special price please call or e-mail our support.

Additional information

Weight 1 kg
gift_message_available

0

naya_call_for_price_enable

1

short_description

<p>Features</p>
<p>Multiple-Echo for reliable, accurate through coating measurements<br />Single-Echo and Echo-Echo measuring modes with twin crystal probes for extreme corrosion and back wall pitting<br />A-scan display<br />Real time B-scan display<br />Manual and automatic gain control<br />Comprehensive data logging capabilities<br />Bluetooth connectivity<br />MSI™ (Measurement Stability Indicator) used in Single‑Echo and Echo-Echo measurement modes<br />Large bright colour LCD screen with back light<br />Deep-coat mode, measure through coatings up to 20 mm thick<br />Wrist mountable<br />Minimum / maximum measurement limit functions with visual and vibrate alert<br />Intuitive easy to use menu<br />Extremely rugged enclosure – shock and impact to US MIL STD 810G<br />Environmental sealing to IP67 – US MIL STD 810G<br />Cygnus echo strength bars to assist quick measurements<br />Buttons integral with the TPE moulding and designed for min 100,000 depressions.</p>

meta_title

Buy Cygnus 6+ PRO Online

msrp

2.000000

msrp_display_actual_price_type

4

tax_class_id

2

Leave a Reply

Your email address will not be published. Required fields are marked *